Skip to content

Accessories

Flexible Copper Braid

Suitable for used in transmitting current across conducting mediums that are subjected to different motions by thermal expansion, vibration or operational movement.

Material: Annealed Copper

Finishing: Tin Plated

Cable Lug End Caps

Made from PVC material, these Cable Lug End Caps are used to protect wire and cable ends. 

There are six color options with twenty dimensions for various cable sizes.

Terminal Block

For control, automation, instrumentation and power distribution application. Specifically designed flexible foot enable easy mounting and dismounting from the DIN rail.

Electrical Jointing Compound

Suitable for Aluminium and Copper jointing and termination.

Formulated to improve jointing conductivity and inhibit oxidation/ corrosion between jointing contact areas.

H-2 (Z) Heat Shrink Tubing

Made from cross-linked polyolefin and can be cut into sizes to fit over a cable joint to protect and insulate the connection. 

Shrink ration is 2:1

Wiring Duct

For routing and concealing wiring in cabinets and control panels.

The material is self-extinguishing and flame resistance.

Length: 2 meter

Slot Hole: 8mm

TF Cable Cleats

Specially designed to withstand high mechanical bursting forces associate with fault current encountered in cable installation.

Suitable for fixing single cable with outer diameter ranging from 19mm to 180mm.

Mounting can be done easily on all types of channel.

 

TF Trefoil Cable Cleats

Specially designed to withstand high mechanical bursting forces associate with fault current encountered in cable installation.

Suitable for fixing three cables with outer diameter ranging from 33mm to 120mm. 

PVC Cable Gland

Comes with flexible blades designed for commercial applications that require a good hold on the cables. Cable can be easily inserted into the gland without dismantling of parts.

Material: Polyamide

Working Temperature: -40°C to 80°C

CW Cable Gland

Suitable for both indoor and outdoor applications.

Designed and tested as per BS6121: Part 1: 1989 and meets the requirements of EN 50262 : 1999.

 

G Cable Gland

It provides mechanical cable retention and electrical connectivity for cable termination.

Suitable for indoor applications and for all types of Single Wire Amour (SWA).

A2 Cable Gland

A2 type brass indoor cable gland is used with all types of non-armored cable.

Suitable for all types of electrical power, control, instruments, data and telecommunications cable.

Constant Force Spring

Suitable for bundling copper braids for grounding in cable straight joins and terminations.

Application range: 13-90mm

Heat Shrink Tubing

Operating Temperature Range: -30°C to +125°C

Shrinkage Ratio: 2:1

Material: Cross-link polyolefin

Standard Colours: Red, Yellow, Blue and Black

Heat Shrink Track-Resistant Tubing

Used for medium voltage up to 33kV. Suitable for cable termination and intermediate connecting insulation protection.

Application Diameter Range: 12-75mm

Heat Shrink Insulation Breakout

Used for medium voltage up to 33kV. Suitable for cable termination separation and protection against moisture and pressure. 

Operating Temperature: -40°C to +100°C

Filling Mastic

Used for gap filling for cable terminations and straight joins.

Colour Standard: White

Sealing Mastic

Suitable for waterproofing of straight joints and terminations.

Colour Standard: Red

Heat Shrink Cable End Cap

Used for sealing the ends of power cables, lines and pipes.

Operating Temperature Range: -40°C to to +110°C

Heat Shrink Right Angle Boot

Used for medium voltage up to 33kV. Protection against flashover ad surge.

Application Cable Cross-sectional Range: 11kV: 25-300mm2, 33kV: 25-120MM2 

Heat Shrink Skirt

Used for medium voltage termination up to 33kV. Increase creepage distance, scatter rain. For outdoor use only.

Operating Temperature: -40°C to +110°C

Heat Shrink Busbar Insulation Tubing

Used for medium voltage substations up to 33kV to reduce electric clearance and increase insulation between busbars. Type test: IEC 60684

Operating Temperature Range: -40°C to +100°C